UVMILK® SL Two-level pumping and filtering station
Get the highest possible price for your milk and save on equipment by using compact UVMILK® SL Two-level pumping filtering station which pumps and cleans milk from even smallest contaminations
In stock
EQUIPMENT
- UVMILK® Double filter housing – 1 pc
- UVMILK® SL Slotted filter – 1 pc
- UVMILK® Mini filter cartridges for fine purification of milk – 1 pack
- Milk pump – 1 pc
- Couplings – 2 pcs
- PUMPING AND FILTERING MILK ANYWHERE thanks to a compact mobile device that provides required pressure with the pump
- SAVE ON 3-IN-1 SYSTEM due to advantageous cost of the complete UVMILK® SL pumping and filtering station which includes two filters and a pump at once
- INCREASING MILK GRADE thanks to the solution that includes two filtering levels: preliminary, from large dirt particles, and fine, from minor impurities
- VUSUAL INDICATOR OF MILK PURITY due to snow-white color of primary polypropylene which makes all dirt visible
- EFFICIANT CLEARING FROM LARGE PARTICLES due to special holes structure of the outer slotted filter which holds major impurities in milk
- REDUCE OF BACTERIAL CELL COUNT AND INCREASE OF MILK STORAGE TIMEthanks to inner polypropylene filter of UVMILK® SL station with multilayer winding which clears all impurities over 5 µm
1. Housing (1) and back lid (3) with the seal (6) connect with the clamp (5), screw it (7);
2. Filtering cartridge (4) should be adjusted on one side to the pilot nipple (2), on another side a seal should be installed (6) and the lid (2) fixed to the housing by a clamp (5) and a screw (7);
! The seals for the clamps must fit exactly into the slots on the housing cap and on the branch pipes, then the housing will be completely sealed (2, 3, 6)
! It's important not to confuse «ВХОД» (input) and «ВЫХОД» (output) of the milk flow.
3. Pump
- Use UVMILK® SL Two-level pumping and filtering station while milking when milk is warm to prevent dissolution of impurities.
- The pump motor is connected via a motor-protective circuit breaker.
- The pump is started when the discharge valve is closed and the casing of the pump flow path and the suction pipe are completely filled with liquid.
- Limit the pumped liquid supply with a valve for discharge with obligatory control of the current in the windings. The current should not turn on, the unit is on the nameplate of the electric motor.
- To avoid hydraulic impact, after you install the filter first open the «ВХОД» (input), and then, when the housing fills up with milk, gradually open the «ВЫХОД» (output).
- After milking flush UVMILK® slotted filter cartridge with reverse sanitizing water flow, no need to disassemble it.
- After the declared amount of milk passes through the filter or after you finish milking, remove the replaceable cartridge and dispose of it together with other solid waste.
- One filtering cartridge should be used for one milking only.
- Wash the milking system each time and use a new filtering cartridge for each milking to prevent bacterial cell grow and milk go sour.
- The seals for the clamps must fit exactly into the slots on the housing cap and on the branch pipes, then the housing will be completely sealed.
- The silicone seals in the housing should be replaced 2 times a year.
Reviews
Suitable for your production
UVMilk LLC — we make filters
for food and petrochemical industry